Replacing a horizontal multistage pump should not mean re-plumbing the plant room. Our BPI and BPIL series follow the size classes most commonly installed for this duty, in the same model-number steps: find the size class of your current unit in the tables below, read off the burks model with its connections and dimensions, and order with confidence. For any other pump — any brand — send us the nameplate and we will confirm the match in writing, free.
The BPI series — stainless-steel casing, fluid −15~+110 °C, max. pressure 10 bar, IP54 — Dimensions below are burks production figures, listed by size class (single-phase / three-phase variants).
| burks model | Power (kW) | Connections in × out | Length L (mm), 1~ / 3~ | Height H (mm), 1~ / 3~ | Weight (kg), 1~ / 3~ |
|---|---|---|---|---|---|
| BPI 202 | 0.37 | Rp1" × Rp1" | 375 / 375 | 202 / 194 | 9.8 / 8.9 |
| BPI 203 | 0.55 | Rp1" × Rp1" | 375 / 375 | 202 / 194 | 9.8 / 8.9 |
| BPI 204 | 0.55 | Rp1" × Rp1" | 423 / 423 | 202 / 194 | 10.6 / 9.7 |
| BPI 205 | 0.75 | Rp1" × Rp1" | 454 / 434 | 202 / 211 | 12.2 / 11.3 |
| BPI 206 | 1.1 | Rp1" × Rp1" | 478 / 480 | 208 / 218 | 15.7 / 12.9 |
| BPI 402 | 0.55 | Rp1¼" × Rp1" | 375 / 375 | 202 / 194 | 9.8 / 8.9 |
| BPI 403 | 0.55 | Rp1¼" × Rp1" | 375 / 375 | 202 / 194 | 9.8 / 8.9 |
| BPI 404 | 0.75 | Rp1¼" × Rp1" | 454 / 434 | 202 / 211 | 12.2 / 11.3 |
| BPI 405 | 1.1 | Rp1¼" × Rp1" | 454 / 456 | 208 / 218 | 15.2 / 12.9 |
| BPI 406 | 1.5 | Rp1¼" × Rp1" | 509 / 523 | 228 / 240 | 16.7 / 15.2 |
| BPI 802 | 0.75 | Rp1½" × Rp1¼" | 418 / 398 | 202 / 211 | 11.5 / 10.6 |
| BPI 803 | 1.1 | Rp1½" × Rp1¼" | 418 / 420 | 208 / 218 | 14.5 / 12.2 |
| BPI 804 | 1.5 | Rp1½" × Rp1¼" | 509 / 523 | 228 / 240 | 16 / 15.8 |
| BPI 805 | 1.85 | Rp1½" × Rp1¼" | — / 523 | — / 240 | — / 17 |
| BPI 1602 | 1.5 | Rp2" × Rp1½" | — / 483 | — / 240 | — / 15.5 |
| BPI 1603 | 1.85 | Rp2" × Rp1½" | — / 483 | — / 240 | — / 17.7 |
| BPI 1604 | 2.2 | Rp2" × Rp1½" | — / 528 | — / 240 | — / 21.1 |
The BPIL series — cast-iron casing with stainless internals, fluid −15~+90 °C, max. pressure 10 bar, IP54. Dimensions below are burks production figures, listed by size class.
| burks model | Power (kW) | Connections in × out | Length L (mm), 1~ / 3~ | Height H (mm), 1~ / 3~ | Weight (kg), 1~ / 3~ |
|---|---|---|---|---|---|
| BPIL 202 | 0.37 | Rp1" × Rp1" | 360 / 360 | 220 / 194 | 10.8 / 10.8 |
| BPIL 203 | 0.55 | Rp1" × Rp1" | 360 / 360 | 220 / 194 | 11.5 / 11.5 |
| BPIL 204 | 0.55 | Rp1" × Rp1" | 384 / 384 | 220 / 194 | 12.5 / 12.5 |
| BPIL 205 | 0.75 | Rp1" × Rp1" | 439 / 420 | 209 / 211 | 16.5 / 17.8 |
| BPIL 206 | 1.1 | Rp1" × Rp1" | 463 / 442 | 209 / 218 | 19.7 / 19.7 |
| BPIL 402 | 0.55 | Rp1¼" × Rp1" | 360 / 360 | 220 / 194 | 10.9 / 11 |
| BPIL 403 | 0.55 | Rp1¼" × Rp1" | 360 / 360 | 220 / 194 | 11.5 / 11.6 |
| BPIL 404 | 0.75 | Rp1¼" × Rp1" | 415 / 396 | 209 / 211 | 17.1 / 17.1 |
| BPIL 405 | 1.1 | Rp1¼" × Rp1" | 439 / 442 | 209 / 218 | 17.9 / 17.9 |
| BPIL 406 | 1.5 | Rp1¼" × Rp1" | 516 / 510 | 229 / 240 | 22.9 / 22.9 |
| BPIL 802 | 0.75 | Rp1½" × Rp1¼" | 410 / 391 | 209 / 211 | 15.5 / 15.5 |
| BPIL 803 | 1.1 | Rp1½" × Rp1¼" | 410 / 407 | 209 / 218 | 16.6 / 16.6 |
| BPIL 804 | 1.5 | Rp1½" × Rp1¼" | 493 / 480 | 229 / 240 | 21.6 / 21.6 |
| BPIL 805 | 1.85 | Rp1½" × Rp1¼" | — / 510 | — / 240 | — / 23.6 |
What matches, stated exactly: the threaded inlet and outlet connections are the same sizes as the unit you are replacing, so the pump connects straight onto the existing pipework. Overall dimensions and mounting details are burks' own production figures as tabled here; on some models they can differ slightly from the unit you are replacing, so check L, H and the mounting against your space before ordering — or send us the old nameplate and we will confirm the swap in writing before you pay.
Vertical multistage: our BV/BN in-line vertical multistage range covers rated flows of 1–260 m³/h and heads to 366 m. Vertical ranges are not numbered alike between brands, so send the duty point or the nameplate and an engineer will match from the curves.
Sewage lifting: replacing a packaged macerator unit or an ageing lifting station? Start with the B-Lift family — external-pump stations that can be serviced dry — and tell us the fixtures and lift height.
Any other pump: a clear photo of the nameplate is enough. We reply with the closest burks model, the dimension check and a quotation — normally within one business day.
Photo of the nameplate, or just the model and duty point — an engineer confirms the replacement in writing, normally within one business day (Mon–Fri, Beijing time).
Inquiry Form WhatsApp: +86 137 3919 8887Email: burkspumps@gmail.com