  • The burks type submersible pump electric pump light BKL
The burks type submersible pump electric pump light BKL

The burks type submersible pump electric pump light BKL

  • Product description: burks specializes in BKL sewage pump series products, with a professional sales and technical service team.
  • INQUIRY

USER MANUAL

Tap or scan
to view on phone
Online preview









BKL系列轻巧型潜水泵

特性
1.不锈钢一体成型无接缝冲压外壳,外壳防护高。
2.电机线圈内藏温度过热保护装置,保护电机不过热烧毁。
3.放悬吊叶轮设计,ZK流通道,不卡住底盘。
4.特殊工程塑化叶轮、出口管、脚座,不生锈并具耐磨耗特性。
5.轻巧美观:坚固耐用、轻置化设计,提取、搬运容易。使用免安装、免维护保 养、操
作简便、随插即用。
6.BKL系列外观涂装采用EPOXY环氧树脂,防锈耐蚀性兼顾。
用途
1.家庭、生活污水、地下室积水、下水道沟渠污水排放。
2.洗车、花园浇水、小流量景观流水设计抽排放水。
3.池水塘、化粪池水等机关社区机能性污废水排放。
4.小型工厂作业性一般污废水循环使用或抽排放。
5.大楼化粪池水、猪畜牧业等之排泄废水排放。
6.原水、抽水站、污水处理厂等局部抽排放水使用。
Characteristic
1. stainless steel one-piece non joint stamping shell with high enclosure protection.
2. the motor coil is protected by a temperature overheating protection device to protect the motor
from overheating.
3. put the suspension impeller design, ZK flow channel, do not block the chassis.
4. special engineering plasticizing impeller, outlet pipe and foot seat are not rusty and wear
resistant.
5. lightweight and beautiful: durable, lightweight design, easy to extract and transport. It is free of
installation, maintenance free, easy to operate and plug and play.
6.BKL series exterior coating is made of EPOXY epoxy resin with both rust and corrosion
resistance.
Purpose
1. discharge of sewage from household, domestic sewage, basement water, sewer and ditch.
2. car wash, garden watering, small flow landscape water design drainage drainage.
3. pool sewage, septic tanks, water and other organs of community functional waste water
discharge.
4. small factories operate in general waste water recycling or pumping.
5. waste water from building septic tanks and pig farms.
6. local water, pumping stations, sewage treatment plants and other local drainage and drainage.


Model Description

This series has 8 models: BKL-1057(A), BKL-3057, BKL-115(A), BKL-315, BKL-118(A), BKL-318, BKL-128(A) and BKL-328. BKL-1057(A), BKL-115(A), BKL-118(A) and BKL-128(A) are single-phase 220V, while BKL-3057, BKL-315, BKL-318 and BKL-328 are three-phase 380V; the (A) in the model name indicates a 220V motor fitted with an automatic float switch. Rated output is 0.4–1.5kW, outlet diameter 50mm (2 inch) or 80mm (3 inch), speed 2850rpm (2P); standard head 5–10m, standard capacity 9–21m³/h, maximum head 8.5–17m, maximum capacity 15–42m³/h, maximum solids passage 35mm, weight 13–21.5kg. For the detailed flow and head parameters of each model, please refer to the user manual.

Performance Curve

burks BKL series lightweight submersible pump performance curve (50Hz)

BKL series performance curve (50Hz)

Installation Dimensions

burks BKL series lightweight submersible pump installation dimension side view (with minimum continuous-running water level mark)

Installation dimension side view (D, E, F and minimum continuous-running water level)

burks BKL series lightweight submersible pump installation dimension top view

Installation dimension top view (A, B, C)

For the A–F overall dimensions of each model, please refer to the user manual.

Installation and Operating Precautions

(1) When lifting or moving the pump or equipment, pull the handle; never pull the cable, to avoid electric leakage.
(2) During transport, avoid collision and handle with care.
(3) When using this product, fit a leakage circuit breaker to prevent electric shock accidents caused by insulation deterioration as the product ages.
(4) Power voltage check: (A) single-phase: 220V; (B) three-phase: 380V; (C) when the pump runs under load, check whether the voltage is sufficient (the voltage must be the same as stated on the nameplate).
(5) The pump must be used at the rated voltage; the allowable voltage variation must be within ±10%.
(6) Be sure to use the grounding wire (the green core wire is the grounding wire).
(7) Power frequency check: before use, confirm that the power frequency marked on the product is consistent with the frequency used.
(8) If the cable is not long enough and must be extended: when extending the cable, note that an improper extension in wire thickness, size and length will cause voltage drop, difficult motor starting and shortened product life. The cable joint must not be placed in water.
(9) Confirm the rotation direction: (A) single-phase: the rotation direction is fixed before leaving the factory. (B) three-phase: if it runs in reverse, simply swap any two of the three power wires (if the pump runs in reverse, it will vibrate strongly, sound abnormal, deliver less water, and may cause the motor to burn out).
(10) Confirm that starting is normal; if it cannot start, check whether the impeller is stuck due to rust.
(11) Do not let the pump be buried in sludge or sand, and do not let debris block the pump piping; raise the pump on a pad where possible so that the pump bottom is exposed.
(12) Use piping of the same specification as the pump for drainage; using piping smaller than the pump outlet will increase the head loss and reduce the discharge due to improper piping, so please take note.
(13) When the pump is running, the water level must not be lower than the pump body; without water cooling the motor temperature rises quickly and the motor will burn out.
(14) Warning! The pump must not be used for flammable or explosive liquids such as gasoline, fuel oil or kerosene, and must not be used in flammable or explosive places.

Inspection, Repair and Maintenance

Every pump makes a normal sound when running. If during use the head, current, vibration or sound is found to be extremely different from usual, it is mostly a sign of an impending fault; inspection and repair must be carried out immediately. The fault troubleshooting below is attached for your reference. When inspecting the pump on site, be sure to switch off the power before inspection.

(1) Clearing debris from the pump: after pumping water containing silt, especially water containing cement, be sure to let clean water flow through the pump for a few minutes before stopping, to wash the inside of the pump. Otherwise silt, cement or debris will block the impeller and the pump body, and the pump will not start next time.
(2) Insulation resistance: check monthly. Use a 500V insulation resistance meter to measure the insulation resistance between each phase of the motor and the grounding wire, and confirm that it is above 10MΩ (if the result is below 10MΩ, repair immediately).
(3) Shaft seal and lubricating oil inspection: the life of the shaft seal device, calculated on pumping clean water, is about 5000–6000 hours, so check the lubricating oil at least every half year. When the lubricating oil becomes turbid or develops bubbles, repair immediately and replace the shaft seal and lubricating oil.
(4) Storage: before storing, if the lubricating oil check, impeller wear check and insulation resistance check are done first, the pump can be used immediately next time without waiting (and if repair is needed, there is ample time to do it). The inside and outside of the pump can also be washed with clean water; after the water has completely dried, store it in a dry indoor place.

Fault Maintenance

No sound at all and does not run after power is connected

Broken cable → Replace the cable
Poor power line contact → Make a complete connection
Broken motor copper wire → Repair and rewind
Protector activated → Trace the cause of activation and deal with it
Defective protector → Replace the overload protector
Blown fuse → Replace the fuse

Slight sound, but does not run

Single-phase open-phase state of a three-phase pump due to poor contact → Connect completely
Open-phase state of a three-phase pump caused by poor switch contact → Adjust the contact parts
Open-phase state of a three-phase pump caused by a broken cable core → Replace
Open-phase state of a three-phase pump caused by a blown fuse → Replace
Open-phase state of a three-phase pump caused by poor outlet wire contact → Connect completely
Single-phase broken motor copper wire → Repair and rewind
Restrained state caused by a defective bearing → Replace
Defective capacitor of a single-phase pump → Replace
Defective centrifugal switch of a single-phase pump → Replace
Impeller restrained → Remove the impeller and clear the debris
Voltage drop → Adjust the power supply voltage
Insufficient generator capacity → Replace with a larger capacity

Stops immediately after starting

Voltage drop → Adjust the power supply voltage
Insufficient generator capacity → Replace with a larger capacity
Unbalanced voltage of a three-phase pump → Adjust the power supply
Defective protector → Replace
Defective motor copper wire → Repair and rewind
Viscosity of the pumped liquid too high → Consult the dealer
Mixing ratio of the pumped liquid too high → Consult the dealer
Temperature of the pumped liquid too high → Consult the dealer
Reverse running of a three-phase pump → Swap two of the three phases

Insufficient discharge or cannot pump water

Operating head too high, resulting in insufficient water → Select a suitable pump and replace
Excessive head loss → Select a suitable pump and replace
Reverse running of a three-phase pump → Swap two of the three phases
Outlet pipe blocked → Straighten the outlet pipe so the water flows smoothly
Worn impeller → Replace the impeller
Defective bearing → Replace
Strainer blocked → Clear debris from the strainer

Severe vibration

Impeller unevenly worn → Replace the impeller
Reverse running → Swap two of the three phases
Defective bearing → Replace
Excessive air sucked in while pumping → Review the pump installation state

Electric leakage when touching the pump

Insulation degraded, leakage → Stop using and repair

Warranty Certificate

1. This certifies that the products listed below are warranted by our company and have passed strict quality control and inspection under our company's quality management system.
2. Please keep this certificate properly; if lost, it will not be reissued. Thank you for your understanding.
3. This product is warranted for one year from the date of purchase against non-man-made faults under normal use.
4. After the period stated above, if parts need to be replaced, the customer will be charged the parts cost and a service fee.
5. Our company frequently improves its products; if parts must be replaced during the warranty period, our company may replace them with improved parts.
6. Our company is not responsible for warranty for faults caused by force majeure (such as natural disasters) or by man-made factors of the user.
7. Installation of this product should be carried out by professionals according to the key points of use; otherwise our company is not responsible for any fault caused by improper installation.
8. Please test-run and accept the product immediately after delivery; if there is any objection to product quality, please raise it within one week, otherwise our company will not be responsible.

立即咨询·免费选型报价