This series has 8 models: BKL-1057(A), BKL-3057, BKL-115(A), BKL-315, BKL-118(A), BKL-318, BKL-128(A) and BKL-328. BKL-1057(A), BKL-115(A), BKL-118(A) and BKL-128(A) are single-phase 220V, while BKL-3057, BKL-315, BKL-318 and BKL-328 are three-phase 380V; the (A) in the model name indicates a 220V motor fitted with an automatic float switch. Rated output is 0.4–1.5kW, outlet diameter 50mm (2 inch) or 80mm (3 inch), speed 2850rpm (2P); standard head 5–10m, standard capacity 9–21m³/h, maximum head 8.5–17m, maximum capacity 15–42m³/h, maximum solids passage 35mm, weight 13–21.5kg. For the detailed flow and head parameters of each model, please refer to the user manual.
BKL series performance curve (50Hz)
Installation dimension side view (D, E, F and minimum continuous-running water level)
Installation dimension top view (A, B, C)
For the A–F overall dimensions of each model, please refer to the user manual.
(1) When lifting or moving the pump or equipment, pull the handle; never pull the cable, to avoid electric leakage.
(2) During transport, avoid collision and handle with care.
(3) When using this product, fit a leakage circuit breaker to prevent electric shock accidents caused by insulation deterioration as the product ages.
(4) Power voltage check: (A) single-phase: 220V; (B) three-phase: 380V; (C) when the pump runs under load, check whether the voltage is sufficient (the voltage must be the same as stated on the nameplate).
(5) The pump must be used at the rated voltage; the allowable voltage variation must be within ±10%.
(6) Be sure to use the grounding wire (the green core wire is the grounding wire).
(7) Power frequency check: before use, confirm that the power frequency marked on the product is consistent with the frequency used.
(8) If the cable is not long enough and must be extended: when extending the cable, note that an improper extension in wire thickness, size and length will cause voltage drop, difficult motor starting and shortened product life. The cable joint must not be placed in water.
(9) Confirm the rotation direction: (A) single-phase: the rotation direction is fixed before leaving the factory. (B) three-phase: if it runs in reverse, simply swap any two of the three power wires (if the pump runs in reverse, it will vibrate strongly, sound abnormal, deliver less water, and may cause the motor to burn out).
(10) Confirm that starting is normal; if it cannot start, check whether the impeller is stuck due to rust.
(11) Do not let the pump be buried in sludge or sand, and do not let debris block the pump piping; raise the pump on a pad where possible so that the pump bottom is exposed.
(12) Use piping of the same specification as the pump for drainage; using piping smaller than the pump outlet will increase the head loss and reduce the discharge due to improper piping, so please take note.
(13) When the pump is running, the water level must not be lower than the pump body; without water cooling the motor temperature rises quickly and the motor will burn out.
(14) Warning! The pump must not be used for flammable or explosive liquids such as gasoline, fuel oil or kerosene, and must not be used in flammable or explosive places.
Every pump makes a normal sound when running. If during use the head, current, vibration or sound is found to be extremely different from usual, it is mostly a sign of an impending fault; inspection and repair must be carried out immediately. The fault troubleshooting below is attached for your reference. When inspecting the pump on site, be sure to switch off the power before inspection.
(1) Clearing debris from the pump: after pumping water containing silt, especially water containing cement, be sure to let clean water flow through the pump for a few minutes before stopping, to wash the inside of the pump. Otherwise silt, cement or debris will block the impeller and the pump body, and the pump will not start next time.
(2) Insulation resistance: check monthly. Use a 500V insulation resistance meter to measure the insulation resistance between each phase of the motor and the grounding wire, and confirm that it is above 10MΩ (if the result is below 10MΩ, repair immediately).
(3) Shaft seal and lubricating oil inspection: the life of the shaft seal device, calculated on pumping clean water, is about 5000–6000 hours, so check the lubricating oil at least every half year. When the lubricating oil becomes turbid or develops bubbles, repair immediately and replace the shaft seal and lubricating oil.
(4) Storage: before storing, if the lubricating oil check, impeller wear check and insulation resistance check are done first, the pump can be used immediately next time without waiting (and if repair is needed, there is ample time to do it). The inside and outside of the pump can also be washed with clean water; after the water has completely dried, store it in a dry indoor place.
No sound at all and does not run after power is connected
Broken cable → Replace the cable
Poor power line contact → Make a complete connection
Broken motor copper wire → Repair and rewind
Protector activated → Trace the cause of activation and deal with it
Defective protector → Replace the overload protector
Blown fuse → Replace the fuse
Slight sound, but does not run
Single-phase open-phase state of a three-phase pump due to poor contact → Connect completely
Open-phase state of a three-phase pump caused by poor switch contact → Adjust the contact parts
Open-phase state of a three-phase pump caused by a broken cable core → Replace
Open-phase state of a three-phase pump caused by a blown fuse → Replace
Open-phase state of a three-phase pump caused by poor outlet wire contact → Connect completely
Single-phase broken motor copper wire → Repair and rewind
Restrained state caused by a defective bearing → Replace
Defective capacitor of a single-phase pump → Replace
Defective centrifugal switch of a single-phase pump → Replace
Impeller restrained → Remove the impeller and clear the debris
Voltage drop → Adjust the power supply voltage
Insufficient generator capacity → Replace with a larger capacity
Stops immediately after starting
Voltage drop → Adjust the power supply voltage
Insufficient generator capacity → Replace with a larger capacity
Unbalanced voltage of a three-phase pump → Adjust the power supply
Defective protector → Replace
Defective motor copper wire → Repair and rewind
Viscosity of the pumped liquid too high → Consult the dealer
Mixing ratio of the pumped liquid too high → Consult the dealer
Temperature of the pumped liquid too high → Consult the dealer
Reverse running of a three-phase pump → Swap two of the three phases
Insufficient discharge or cannot pump water
Operating head too high, resulting in insufficient water → Select a suitable pump and replace
Excessive head loss → Select a suitable pump and replace
Reverse running of a three-phase pump → Swap two of the three phases
Outlet pipe blocked → Straighten the outlet pipe so the water flows smoothly
Worn impeller → Replace the impeller
Defective bearing → Replace
Strainer blocked → Clear debris from the strainer
Severe vibration
Impeller unevenly worn → Replace the impeller
Reverse running → Swap two of the three phases
Defective bearing → Replace
Excessive air sucked in while pumping → Review the pump installation state
Electric leakage when touching the pump
Insulation degraded, leakage → Stop using and repair
1. This certifies that the products listed below are warranted by our company and have passed strict quality control and inspection under our company's quality management system.
2. Please keep this certificate properly; if lost, it will not be reissued. Thank you for your understanding.
3. This product is warranted for one year from the date of purchase against non-man-made faults under normal use.
4. After the period stated above, if parts need to be replaced, the customer will be charged the parts cost and a service fee.
5. Our company frequently improves its products; if parts must be replaced during the warranty period, our company may replace them with improved parts.
6. Our company is not responsible for warranty for faults caused by force majeure (such as natural disasters) or by man-made factors of the user.
7. Installation of this product should be carried out by professionals according to the key points of use; otherwise our company is not responsible for any fault caused by improper installation.
8. Please test-run and accept the product immediately after delivery; if there is any objection to product quality, please raise it within one week, otherwise our company will not be responsible.
Contact: Peter
Tel: 400-8565-222
Email: burkspumps@Gmail.com