burks pumps
Language: Chinese English

Pump products

  • The burks BKS/AP-200 BKS/AP-400 horizontal automatic constant pressure booster pump
  • The burks BKS/AP-200 BKS/AP-400 horizontal automatic constant pressure booster pump
  • The burks BKS/AP-200 BKS/AP-400 horizontal automatic constant pressure booster pump
  • The burks BKS/AP-200 BKS/AP-400 horizontal automatic constant pressure booster pump
  • The burks BKS/AP-200 BKS/AP-400 horizontal automatic constant pressure booster pump
The burks BKS/AP-200 BKS/AP-400 horizontal automatic constant pressure booster pumpThe burks BKS/AP-200 BKS/AP-400 horizontal automatic constant pressure booster pumpThe burks BKS/AP-200 BKS/AP-400 horizontal automatic constant pressure booster pumpThe burks BKS/AP-200 BKS/AP-400 horizontal automatic constant pressure booster pumpThe burks BKS/AP-200 BKS/AP-400 horizontal automatic constant pressure booster pump

The burks BKS/AP-200 BKS/AP-400 horizontal automatic constant pressure booster pump

  • Product description: burks BKS/AP-200 BKS/AP-400 household booster pump uses electronic principle and water flow control, automatic boost on tap, automatic shutdown on tap.
  • INQUIRY

Introduction

Thank you for using the burks BKS-AP/BKS-APN series products. To fully understand the functions of this product and operate it correctly, please read the instruction manual carefully before installation and use, and keep it properly for quick reference when questions arise during use.

Precautions

Before installation and operation, please strictly follow the installation provisions of the manual to avoid serious harm such as flooding, fire and electric shock caused by incorrect installation and use. If the pump is damaged due to installation not in accordance with the manual, or personal injury and property loss are caused thereby, the company shall not be held responsible.

BKS-AP/BKS-APN Product Description

The BKS-AP/BKS-APN series all use IC control boards. They are constant-pressure water supply systems integrating the water pump, motor, pressure tank and electronic controller, suitable for pressurizing clean water without impurities in general. During use, the electronic controller controls the start and stop of the booster according to changes in water pressure, so as to provide a stable water supply. They contain no toxic substances harmful to the human body, are durable and rust-free, non-toxic and pollution-free, making your water use more assured.

  • Double dry-run protection: in addition to the built-in temperature protection switch of the pump, program-controlled dry-run protection is provided, and the pump stops automatically when there is no water.
  • 6-second delayed stop function; it avoids frequent start-stop of the pump caused by too small water consumption during use.

Features

  • Quiet
  • SUS 304 stainless steel impeller
  • Constant pressure control
  • Thermal protection
  • Dry-run protection

Specification Table (Single Phase 50Hz)

BKS/AP-200

Power200W
Voltage220V
Starting pressure1.5kg
Inlet1"
Outlet1"
Max. head22m
Max. flow50L/min
Weight7.5kg
Installation size A400mm
Installation size B190mm
Installation size C185mm

BKS/AP-400

Power400W
Voltage220V
Starting pressure1.8kg
Inlet1"
Outlet1"
Max. head27m
Max. flow60L/min
Weight8.5kg
Installation size A400mm
Installation size B190mm
Installation size C185mm

BKS/AP-800

Power800W
Voltage220V
Starting pressure2.0kg
Inlet1"
Outlet1"
Max. head28m
Max. flow120L/min
Weight10.8kg
Installation size A391mm
Installation size B144mm
Installation size C149mm

BKS/AP-800H

Power800W
Voltage220V
Starting pressure2.5kg
Inlet1"
Outlet1"
Max. head46m
Max. flow105L/min
Weight11.3kg
Installation size A409mm
Installation size B162mm
Installation size C167mm

Performance Curve

burks BKS/AP series automatic constant pressure <a href=https://www.burks.cn/en/product/BKN-booster-pump.html target='_blank'>Booster pump</a> performance curve

Operating Conditions

  • Ambient temperature: +4℃ to +40℃
  • Liquid temperature: +4℃ to +40℃; BKS-APN series +4℃ to +90℃
  • Relative humidity: Max. 85% (RH)
  • Structural pressure resistance: Max. 8.5kg/cm²
  • Working pressure: Max. 5kg/cm²; the pump is equipped with an automatic pressure relief valve, which relieves pressure automatically when the pressure inside the pump exceeds 5kg/cm², to ensure safe use
  • Inlet pressure: must be less than the starting pressure
  • Suction depth 6m; groundwater with excessively high iron or lime content is not suitable

burks BKS/AP series constant pressure <a href=https://www.burks.cn/en/product/BKN-booster-pump.html target='_blank'>Booster pump</a> operating conditions diagram

Starting pressure and pressure tank pressure of each model:

ModelStarting pressure / Tank pressure
BKS/AP-2001.5kg/cm² / 0.8kg/cm²
BKS/AP-4001.8kg/cm² / 1.0kg/cm²
BKS/AP-8002.0kg/cm² / 1.0kg/cm²
BKS/AP-800H2.5kg/cm² / 1.2kg/cm²

Reference for Number of Faucets

ModelNumber of faucets
BKS/AP(N)2004
BKS/AP(N)2005
BKS/AP8008
BKS/AP800H5

The water output of one faucet is calculated at 15L/min.

Installation Dimensions

burks BKS/AP series constant pressure <a href=https://www.burks.cn/en/product/BKN-booster-pump.html target='_blank'>Booster pump</a> installation dimensions

Installation Instructions

Note: when installing the inlet and outlet water pipes, be sure to use the original flanges and new screws supplied with this machine.

1. The water pump must be installed by licensed professionals, and the power supply wiring must comply with electrical regulations.
2. Wire the power strictly according to the wiring diagram and install a no-fuse breaker to avoid motor burnout or fire.
3. The installation site must be protected from sun and rain, and must not be installed indoors, on ceilings, carpets or near electrical equipment, so as to prevent water leakage from damaging decoration or other electrical facilities.
4. The installation site must have a drain hole with a diameter greater than 32mm, and it must be kept unobstructed. (The drain hole must be large enough to discharge leaked water to prevent flooding)

burks BKS/AP series constant pressure <a href=https://www.burks.cn/en/product/BKN-booster-pump.html target='_blank'>Booster pump</a> drain hole installation diagram

5. Confirm the power supply before energizing, and install a leakage circuit breaker and grounding wire properly to ensure safe use.

burks BKS/AP series constant pressure <a href=https://www.burks.cn/en/product/BKN-booster-pump.html target='_blank'>Booster pump</a> leakage protector and grounding diagram

9. The installation site must reserve maintenance space and be kept dry and ventilated.

burks BKS/AP series constant pressure <a href=https://www.burks.cn/en/product/BKN-booster-pump.html target='_blank'>Booster pump</a> maintenance space diagram

10. Install the pump as close to the water source as possible; excessive distance will reduce efficiency.
11. Pipes and joints must be properly sealed. Leakage at the outlet end will cause frequent starting of the pump and easy failure; poor sealing of the suction pipe will cause the pump to lose its water suction function and run dry. Do not install a vent pipe on the inlet pipeline, because the vent pipe will cause the pump to suck in air and run dry; prolonged dry running will damage the shaft seal and raise the water temperature inside the pump, causing pipeline rupture. Leakage at the outlet end will cause frequent starting of the pump and easy failure.
12. Use sturdy, good-quality water pipes for the outlet pipeline to prevent deformation and rupture of the pipeline caused by excessive pipe pressure or abnormal liquid temperature.
13. Dry running is strictly prohibited. During operation the water temperature must not exceed 40℃, and the use of liquids other than water is strictly prohibited. (For temperatures above 40℃, the BKS-APN series hot-water booster motors can be used, with a maximum water temperature of 90℃)
14. When used with a water heater, the hot water steam will generate high pressure; install a check valve at the outlet piping to protect the pressure tank for safety.
15. It can be used for rooftop pressurization, but if the inlet pipeline has a vent pipe, the pump will suck in air and run continuously; in this case the vent pipe can be removed.
16. During water shortage or water cut-off, turn off the power to prevent the motor from running continuously and being damaged.

Operation Instructions

Dry running is strictly prohibited. After the pump is installed, fill the pump chamber with water according to the following steps before the pump can operate normally. Before turning on the power, confirm that the power supply voltage matches the motor specifications, and install a leakage circuit breaker and grounding wire to avoid accidental electric shock.

a: Unscrew the water filling plug; b: Fill the pump chamber with water.

burks BKS/AP series constant pressure <a href=https://www.burks.cn/en/product/BKN-booster-pump.html target='_blank'>Booster pump</a> priming operation diagram

立即咨询·免费选型报价