burks pumps
Language: Chinese English

Pump products

  • burks BKN Series Canned Motor Pump
burks BKN Series Canned Motor Pump

burks BKN Series Canned Motor Pump

  • Models: 13, BKN-201EH to BKN-1500QH
  • Power: 320-1950 W (EH 220 V / QH 380 V)
  • Max. flow 28 m3/h; max. head 32 m
  • Liquid: 0-90 C; ports 25-50 mm
  • Product description: The burks BKN series canned pump is a hot/cold water canned circulator: sealless, leak-free, quiet and low-consumption, HT200 cast iron casing, PPO/stainless impeller, motor thermal protection. 13 mod
  • INQUIRY

USER MANUAL

Tap or scan
to view on phone
Online preview

Overview

The BKN series canned pump is a hot/cold water canned circulator. Its hydraulic part consists of the pump casing and impeller: the casing is HT200 cast iron and the impeller is PPO modified engineering plastic / stainless steel. The motor has a built-in thermal protector that cuts the circuit when the winding temperature exceeds the limit and restarts the motor when the temperature falls back - safe and reliable. For circulation duty in domestic central hot-water, air-source and solar systems.

From the manual (Chinese): introduction, working conditions and dimensions

Features

● Canned construction: sealless, leak-free, quiet and low energy consumption
● HT200 cast iron casing; PPO / stainless steel impeller, corrosion resistant
● Built-in motor thermal protection with automatic restart
● 13 models: EH single-phase 220 V, QH three-phase 380 V; 320-1950 W, max. flow 5-28 m3/h, max. head 16-32 m, ports 25-50 mm

Technical data (table 7.1)
Model Supply Input W Current A Max head m Max flow m3/h Rated head m Rated flow m3/h Port mm Weight kG Pressure bar
BKN-201EH 1~220V 50Hz 320 1.5 16 5 10 3 25 7 5
BKN-402EH 1~220V 50Hz 720 3.2 23 6.5 16 4 32 10 5
BKN-403EH 1~220V 50Hz 660 3.2 23 6.5 16 4 25 10 5
BKN-601EH 1~220V 50Hz 880 4 28 7.5 20 4 25 11.5 5
BKN-750EH 1~220V 50Hz 1100 5.1 26 12 18 6.6 32 12.5 4
BKN-751EH 1~220V 50Hz 1250 6 32 7.5 20 5 32 13 4
BKN-1100EH 1~220V 50Hz 1500 7.2 30 16 23 8 40 19 4
BKN-1500EH 1~220V 50Hz 1950 10 24 28 20 16 50 21 4
BKN-601QH 1~380V 50Hz 880 4 28 7.5 20 4 25 11.5 5
BKN-750QH 1~380V 50Hz 1100 5.1 26 12 18 6.6 32 12.5 4
BKN-751QH 1~380V 50Hz 1250 6 32 7.5 20 5 32 13 4
BKN-1100QH 1~380V 50Hz 1500 7.2 30 16 23 8 40 19 4
BKN-1500QH 1~380V 50Hz 1950 10 24 28 20 16 50 21 4

From the manual (Chinese): data table and performance curves

From the manual (Chinese): maintenance and troubleshooting

Working conditions and applications

● Ambient temperature 0-40 C, liquid temperature 0-90 C, altitude <1000 m
● Circulation for domestic central hot-water systems, air-source heat pumps, solar systems and similar
● Warranty: one year for non-man-made faults under normal use

立即咨询·免费选型报价