How to Calculate Head and Flow Rate for a Deep Well Submersible Pump: Determine the Dynamic Water Level First, Then Check the Curve

When buying a deep well submersible pump, many people only provide the well depth and then ask how much power is enough. This approach easily leads to errors: well depth is not the same as head, and power is not the starting point for selection. What really needs to be calculated first for a deep well submersible pump is two things—how much flow rate is required, and how much head is required at that flow rate. Together, these two figures form the operating point to check against the product curve.

First, calculate the flow rate. Flow rate is how much water needs to be pumped per unit of time. Estimate it based on simultaneous water use; do not simply add up all water points, and do not calculate based on just one tap. For a household private well, focus mainly on the water points used simultaneously, such as bathrooms, kitchen and laundry. For rural irrigation, work backward from the irrigation area and the planned completion time to determine the required water volume per hour. For refilling a water tank or water tower, calculate by dividing the refill volume by the desired refill time. There is also a prerequisite: the selected flow rate must not exceed the amount of water the well can stably produce. If you pump faster than the well recovers, the dynamic water level will keep dropping, and no matter how large the pump is, it cannot keep up.

burks deep well submersible pump

Next, calculate the head. Head is the sum of four items: first, the vertical height from the dynamic water level to the outlet. Note that this uses the dynamic water level that stabilizes during pumping, not the static water level when the pump is stopped, and certainly not the total well depth. This is a point often confused even in top-ranking articles, some of which directly substitute well depth, resulting in a biased head calculation. Second, pipeline loss, which depends on pipe length, pipe diameter and the number of elbows. The longer, thinner and more elbows the pipeline has, the greater the loss. Third, the pressure required at the outlet. For example, if water is delivered to an open tank, the required pressure is low; if it is delivered to water points and must maintain a certain water pressure, this pressure must be converted into meters and added. As a rough conversion, about 1 kg of pressure corresponds to about 10 meters of head. Fourth, an appropriate margin. Generally, a small margin added to the calculated result is sufficient. If the margin is too large, the pump will operate away from its suitable operating condition for long periods, wasting electricity and damaging the equipment.

Here is a worked example under assumed conditions to aid understanding. The figures are only to demonstrate the calculation method and do not correspond to a specific model: For a certain well, the dynamic water level during pumping is 40 meters below ground, and the water is delivered to a tank 6 meters above ground, so the vertical height is 46 meters. The pipeline is relatively long, so the pipeline loss is estimated at 6 meters. The tank is open for inlet, so the outlet pressure is taken as 2 meters. The four items total 54 meters. Adding a margin of about 10%, the required head is about 60 meters. During selection, use the previously calculated flow rate and this 60-meter head to find the intersection point on the performance curve in the manual, and check whether the intersection falls within the appropriate range of the curve. Do not just look at the maximum head or maximum flow rate marked on the product—those two values do not occur simultaneously under the same operating condition, and treating them as usable values is a common misreading.

Organized into an actionable five-step checklist: 1. Measure or confirm with the well driller the dynamic water level and the well's stable water yield. 2. Calculate the flow rate based on simultaneous water demand. 3. Calculate the vertical height starting from the dynamic water level, add pipeline loss and outlet pressure, then add an appropriate margin to obtain the head. 4. Use the flow rate and head figures to check the operating point on the product curve. 5. Then check whether the well diameter can accommodate the pump body, and whether the power supply conditions and sand content meet the product requirements. Confirm these before finalizing the model. If the dynamic water level or curve verification is missing from these five steps, the selection is prone to deviation.

A safety reminder: deep well submersible pump installation involves lowering into the well, cables and wiring. It must be operated by professionals after power is disconnected. The wellhead must be protected, the pump must not be allowed to run dry, and do not force a model selection based on experience when parameters are uncertain.

If you have already measured the dynamic water level, well diameter and water demand, you can contact us through the contact information on the website page or online customer service. Send us these data, and we will help you check the appropriate deep well submersible pump model against the curve.